Create ’Met_Z’ data logging session and enable
continuous logging
file duration ’60’min
T00 ’off’ Binex ’on’
Binex options
Measurements
’15 Sec’ interval
all optons ’off’
System Status Record ’off’
Metadata
’30 Min’ interval
Site decription ’on’
Station ID ’on’
Firmware Version ’on’
All others ’off’
File naming (The Session Identifier) ’z’
Directory options ’Create Per-SessionID subdirectories’
Set reserve space for ’z’ session data.
Set Autodelete to ’10’ MBytes
Set pool ’z’ size to ’100’ MBytes and enable Autodelete
Reset pool ’c’ size to ’500’ MBytes
Set I/O SerialPort 2 and enable
Service ’Met-Tilt’
Baud 19200
Parity ’None’
Flow Control ’None’
Parameters for Met/Tilt mode
0R0 1 minutes
Article ID: 534
Created: November 20, 2009
Last Updated: November 20, 2009
Author: Beth Bartel
Online URL: https://kb.unavco.org/article/vaisala-how-to-configure-a-trimble-netrs-for-use-with-a-vaisala-wxt510-metpack-in-the-plate-boundary-observatory-534.html