A3LA-SA Remote Modem:
AT&F0: Reset to factory defaults
AT&D0: Ignore DTR input
AT&K0: No flow control
AT+IPR=6,0: Set baud rate to 19200 and disable Autobaud feature
ATS0=1: Answer on first ring
ATQ1: Quiet mode
AT&W0: Write settings to memory register 0
AT&V: View current configuration if desired
A3LA-MPT Base Modem:
AT&F0: Reset to factory defaults
AT&D0: Ignore DTR input
AT&K0: No flow control
AT+IPR=6,0: Set baud rate to 19200 and disable Autobaud feature
AT&W0: Write settings to memory register 0
AT&V: View current configuration if desired
UNAVCO Polar standard configuration settings for Iridium-equipped sites are listed below. Individual settings may vary depending on specific application and/or project PI request.
Commonly modified settings are highlighted in red.
As of April 2009, UNAVCO uses NetRS Firmware 1.1-5 for Polar applications.
Receiver Status:
Identity: Set System Name
Satellites:
GPS Enable/Disable: All Enabled
WAAS Tracking: Off
Data: N/A
Data Logging:
Primary Session: ENABLED
Select Session: 60min, Enabled: Checked
Schedule:
Continuous Logging: Checked
File Durations: 60 minutes
Data Format: T00
T00 Options:
Measurement Interval: 30 Sec
Position Interval: 5 min
Smooth Code Phase: NOT Checked
Smooth Carrier Phase: NOT Checked
File Naming:
āSā (The Session Identifier) is: a
Directory Options:
Create Per-Day Subdirectories: Checked
Secondary Session: NOT ENABLED
Select Session: 1Hz_1hr, Enabled: NOT Checked
Schedule:
Continuous Logging: Checked
File Durations: 60 minutes
Data Format: T00
T00 Options:
Measurement Interval: 1 Sec
Position Interval: 5 Min
Smooth Code Phase: NOT Checked
Smooth Carrier Phase: NOT Checked
File Naming:
āSā (The Session Identifier) is: b
Directory Options:
Create Per-SessionId Subdirectories: Checked
AutoDelete:
Reserved Space: AutoDelete: NOT Checked. (AutoDelete may be desirable for certain applications; consult UNAVCO).
Session Pools: None Defined
Power Saving:
Power Down Between Sessions Mode: No
Failsafe Wakeup Alarm: Yes, for 10 minutes every 24 hours
Receiver Configuration:
Antenna: Enter site-specific antenna parameters
Clock Steering: Enabled
Multipath: Disabled
L2C Tracking: Disabled
Masks:
Elevation Mask: 7
PDOP Mask: 99
One Pulse Per Second: Disabled
Reference Frequency: Internal
Configuration Files: After receiver has final configuration,
create a configuration file named "NAME_config_mm-dd-yy.txt" and download copy to a separate computer.
Shutdown Voltage: 10.680
System Reset: N/A
Internet:
Ethernet:
Static IP:
IP Address: 192.168.1.2
MTU: 1500
Netmask: 255.255.255.0
Gateway: 192.168.1.1
HTTP:
HTTP Standard Port 80: Enabled
HTTP Alternate Port 8080: Disabled
HTTPS Standard Port 443: Enabled
HTTPS Alternate Port 8443: Disabled
IP Filtering: Disabled
FTP:
Anonymous FTP: Enabled without Delete
Named FTP: Disabled
Administration FTP: Disabled
FTP Server Port: Use Standard Port
NTP Client: Disable using NTP time servers
I/O Configuration:
Port Configuration, Serial Port 2: ENABLED
Service: PPP
Baud: 19200
Flow Control: None
Parameters for PPP mode:
Local IP Address: 192.168.xx.2 (xx is two digit number, unique to each site)
Remote IP Address: 192.168.xx.1 (xx is two digit number, unique to each site)
Connection: Direct
Port Configuration, Serial Port 4: ENABLED (optional)
Service: Met-Tilt
Baud: 19200
Parity: None
Flow Control: None
Parameters for Met-Tilt mode:
Command: 0R0
Schedule: 30 minutes
Reference Station: N/A
Client Authentication: N/A
Port Advertising: Disabled
PPP Dialout: N/A
Security:
Access:
System Controls: Unrestricted
GPS Controls: Unrestricted
File Access: Unrestricted
Accounts: N/A
Change Password: N/A
Firmware: 1.1-5
Programmatic Interface: N/A
Article ID: 508
Created: October 27, 2009
Last Updated: October 27, 2009
Author: Beth Bartel
Online URL: https://kb.unavco.org/article/polar-station-netrs-receiver-and-iridium-modem-configuration-508.html