Power up the unit.
Connect to the MSS100 from your PC 9 pin serial port to the 25 pin serial port of the unit (utilizing Hyper-terminal). 9600-8-N-1. Hit enter and the local prompt should appear.
Give privileged status to the port. This will allow you to change the configuration of the unit: "set privileged". The password is "system"
Change the system and login passwords:
change privpass *****
change loginpass *****
TCP/IP parameters (to see the current configuration, type "show server")
change ipaddress 128.117.38.xx
change nameserver 128.117.xx.xx
change subnetmask 255.255.255.0
change gateway 128.117.xx.xx
Serial port configuration (to see the current configuration, type "show ports")
Change speed 19200 (you will loose contact and have to reconnect)
change parity none
change stopbits 1
change flow control none
Emulation a Direct Serial connection
At the local Unit:
change dedicated tcp remoteIP:3001T
change autostart enabled
reboot the unit "I d 0"
At the remote Unit
change access remote
change dedicated none
change autostart disabled
reboot the unit "I d 0"
Issue the command "show ports" to check your configuration.
For correct configuration output, see attached .pdf file.