The mean power consumption during a 12 hour test of the Trimble NetR9 receiver was: 3.67 W



Testing Procedure:
  • Input: 16 V
  • Agilent N6705B DC power analyzer
  • Power sampling rate: 10 Hz
  • Test was conducted at room temperature
  • Tracking GPS L1/L2 only
  • Logging one 15 second session
  • Ethernet port was connected (increases power use by ~0.1W)
  • Connected to a TRM59800.00 antenna
  • USB thumb drive attached (increases power use by ~0.4W)
  • Firmware version 4.43
Attached Files