  1. Create a directory with the name of your project.

  2. Put the base station PC card into the card reader.

  3. Drag the base file(s) into your project directory.

  4. You may wish to rename the file, changing the first 4 numbers to “base”, leaving the Julian day and index number alone.

  5. Right click the file and choose convert to “.DAT” format.

  6. Place the rover’s PC card into the card reader.

  7. Open Trimble Data Transfer.

  8. Select PC card under device. Make sure the green connect button is depressed.

  9. Click the “Add” button.

  10. Select your project directory for the destination directory; click Open.

  11. Highlight your job file with a single click.

  12. Click Transfer All.

Attached Files (1)
Comments
There are no comments for this article. Be the first to post a comment.
Name
Email
Security Code Security Code
Related Articles RSS Feed
Trimble Survey Controller Software for the TSCe - v11.40 Help File
Viewed 1968 times since Fri, Jan 8, 2010
Trimble R7/5700 - System Card
Viewed 2169 times since Thu, Jan 21, 2010
Trimble R7 and 5700 Firmware issue for receivers with FW less than 2.3
Viewed 12357 times since Tue, Mar 1, 2016
Trimble 5700 - How to configure for RTK stakeout surveys
Viewed 2958 times since Tue, Jan 26, 2010
Trimble TSC2 Data Collector and Survey Controller - Complete Quick-start Guide
Viewed 5655 times since Sat, Jan 10, 2009
Trimble 5700/R7 - How to configure for RTK - OLD
Viewed 2975 times since Tue, Jan 26, 2010
Trimble Survey Controller Software for the TSC2 - v12.45 Release Notes
Viewed 2492 times since Fri, Jan 8, 2010
Preliminary Report on Data Quality with a Trimble 5700 GPS Receiver and an Ashtech Choke Ring Antenna (2002)
Viewed 4214 times since Wed, Dec 3, 2008
Trimble R7-R8 - User Guide, v1.00 Rev. A, September 2003
Viewed 1757 times since Mon, Feb 23, 2009
Trimble R8/5800/4800 Resource Page
Viewed 16510 times since Tue, Dec 15, 2009
MENU

Last modified: Monday, 12-May-2014 00:18:29 UTC