  • All values were measured using an Agilent DC Power Analyzer
    • Power consumption was measured at 12 V
  • Measured values are given with 10% margin of error
    • Power values will fluctuate with the number of visible satellites tracked
  • Users must turn off both satellite and signal tracking to realize power consumption reductions
Criteria GPS L1 and L2 only (W) GPS L1, L2, & L5 (W) GPS and GLONASS (W) All Constellations in view (W)
Minimum possible power consumption 2.0 2.3 2.3 3.1
Ethernet Off - Logging 15-sec Session 2.2 2.4 2.4 3.2

Ethernet Off - Logging 15-sec Session &

1 Hz Session

2.2 2.4 2.4 3.2

Ethernet Off - Logging 15-sec Session & 

10 Hz Session

2.2 2.4 2.4 3.2

Ethernet On - Logging 15-sec session &

1 Hz Session

2.9 3.1 3.1 4.0

Ethernet On - Logging 15-sec session &

1 Hz TCP/IP stream

2.9 3.1 3.1 4.0

Ethernet On - Logging 15-sec Session &

1 Hz Session & 10 Hz TCP/IP stream

2.9 3.1 3.1 4.0
Maximum possible power consumption       4.3
Attached Files
There are no attachments for this article.
Comments
There are no comments for this article. Be the first to post a comment.
Name
Email
Security Code Security Code
Related Articles RSS Feed
Javad Sigma Power Consumption
Viewed 6110 times since Wed, Oct 5, 2011
Power - Wind Power Testing at UNAVCO through 2005, Phase 2
Viewed 3395 times since Sat, Mar 27, 2010
Leica GR10 Power Consumption
Viewed 7399 times since Tue, Oct 11, 2011
Power Draw Profile for a Trimble NetRS and Iridium System (polar)
Viewed 4285 times since Sun, Mar 28, 2010
GNSS Antenna Power Consumption Testing
Viewed 5209 times since Wed, Nov 26, 2014
Power - Wind Power Testing at UNAVCO through 2005 (summary)
Viewed 2591 times since Sat, Mar 27, 2010
SLA Battery Cold Performance Tests: Gel vs. AGM
Viewed 14474 times since Sun, Mar 28, 2010
Power - Wind Power Testing at UNAVCO through 2005, Phase 1
Viewed 3433 times since Sat, Mar 27, 2010
Septentrio PolaRx4 Power Consumption
Viewed 3549 times since Thu, Sep 29, 2011
Summary Report on Forgen 500 Wind Turbine Performance (2007)
Viewed 7759 times since Sat, Mar 27, 2010
MENU

Last modified: Monday, 12-May-2014 00:18:29 UTC