The mean power consumption during a 12 hour test of the Septentrio PolaRx4 Pro receiver was: 6.11 W


Testing Procedure:

  • Input: 15 V bias
  • Agilent N6705B DC power analyzer
  • Power sampling rate: 10 Hz
  • The test was conducted at room temperature
  • Tracking GPS L1/L2 only
  • Logging one 15 second session
  • Ethernet port connected (increases power consumption by ~0.1W)
  • Connected to a TRM59800.00 antenna
Note: Changing the receiver’s configuration, antenna, etc. can increase or decrease power consumption.
Attached Files
There are no attachments for this article.
Comments
There are no comments for this article. Be the first to post a comment.
Name
Email
Security Code Security Code
Related Articles RSS Feed
Equipment Power Usage Testing
Viewed 9250 times since Sun, Mar 28, 2010
Power Draw Profile for Trimble NetRS and Iridium Systems
Viewed 6180 times since Sat, Aug 28, 2010
Power - Wind Power Testing at UNAVCO through 2005, Phase 1
Viewed 3738 times since Sat, Mar 27, 2010
SLA Battery Cold Performance Tests: Gel vs. AGM
Viewed 16288 times since Sun, Mar 28, 2010
Trimble NetRS - Power Draw Tests
Viewed 4934 times since Sun, Mar 28, 2010
Topcon Net-G3A Power Consumption
Viewed 3516 times since Mon, Oct 10, 2011
Septentrio PolaRx5 Power Consumption
Viewed 3242 times since Fri, Jan 8, 2016
Power - Wind Power Testing at UNAVCO through 2005, Phase 2
Viewed 3702 times since Sat, Mar 27, 2010
Remote Station Power Analysis (2007)
Viewed 3494 times since Sun, Mar 28, 2010
Summary Report on Forgen 500 Wind Turbine Performance (2007)
Viewed 8155 times since Sat, Mar 27, 2010
MENU
 

Last modified: 2019-12-27  16:36:35  America/Denver