| UNAVCO
 


Knowledge Base

Javad Sigma Power Consumption

The mean power consumption during a 12 hour test of the Javad Sigma receiver was: 3.97 W



Testing Procedure:
  • Input: 12 V
  • Agilent N6705B DC power analyzer
  • Power sampling rate: 10 Hz
  • Test was conducted at room temperature
  • Tracking: GPS L1/L2 only
  • Logging one 15 second session
  • Ethernet port was connected (increases power use when connected)
  • Connected to a TRM59800.00 antenna
  • receiver has no internal batteries
  • receiver set to low power mode (GREIS command: "%%set,/par/pwr/lpm,on")
  • LEDs do not light up when receiver is in low power consumption mode

Attached Files
There are no attachments for this article.
Comments
There are no comments for this article. Be the first to post a comment.
Name
Email
Security Code Security Code
Related Articles RSS Feed
GNSS Antenna Power Consumption Testing
Viewed 5453 times since Wed, Nov 26, 2014
Summary Report on Forgen 500 Wind Turbine Performance (2007)
Viewed 8215 times since Sat, Mar 27, 2010
Power Draw Profile for Trimble NetRS and Iridium Systems
Viewed 6251 times since Sat, Aug 28, 2010
Wind Power for Remote DC Powered Stations (2003)
Viewed 2830 times since Sat, Mar 27, 2010
Topcon Net-G3A Power Consumption
Viewed 3570 times since Mon, Oct 10, 2011
Power - Wind Power Testing at UNAVCO through 2005 (summary)
Viewed 3002 times since Sat, Mar 27, 2010
Power - Wind Power Testing at UNAVCO through 2005, Phase 1
Viewed 3803 times since Sat, Mar 27, 2010
Power - Wind Power Testing at UNAVCO through 2005, Phase 3
Viewed 3984 times since Sat, Mar 27, 2010
Remote Station Power Analysis (2007)
Viewed 3563 times since Sun, Mar 28, 2010
Equipment Power Usage Testing
Viewed 9323 times since Sun, Mar 28, 2010
MENU
 

Last modified: 2019-12-27  16:36:35  America/Denver