| UNAVCO
 


Knowledge Base

GNSS Antenna Power Consumption Testing

The following power tests were conducted on GPS and GNSS antennas using an Agilent N6705 DC Power Analyzer. The following tests show short, 1-minute averages of measured power consumption. The power use of each antenna was tested at two separate voltages. Power use when connected to a receiver will vary depending on the antenna bias voltage of the reciever being used.

If you have questions, contact Henry Berglund (berglund @ unavco.org).

Make Model Bias 1
Power 1
Bias 2
Power 2
Ashtech ASH701945E_M 7.0V
0.295 W
5.0V
0.212 W
Leica LEIAR10 7.0V
0.257 W
5.0V
0.242 W
Leica LEIAR20 7.0V
0.26 W
5.0V
0.25 W
Septentrio SEPTCHOKE_MC 7.0V
0.365 W
5.0V
0.26 W
Septentrio PolaNt_gg 7.0V
0.235 W
5.0V
0.168W
Topcon TPSCR.G3 7.0V
0.212 W
5.0V
0.152 W
Topcon TPSPG_A1+GP 7.0V
0.22 W
5.0V
0.156 W
Topcon TPSG3_A1 7.0V
0.212 W
5.0V
0.149 W
Trimble TRM57971.00 7.0V
0.633 W
5.0V
0.436 W
Trimble
TRM29659-00 7.0V
0.414 W
5.0V
0.265 W
Trimble TRM59800-80 7.0V
0.712 W
5.0V
0.48 W
Trimble
TRM41249.00 7.0V
0.712 W
5.0V
0.506 W
Trimble
TRM39105.00 7.0V
0.737 W
5.0V
0.523 W
Trimble TRM59900-00 7.0V
0.624 W
5.0V
0.448 W
Attached Files
There are no attachments for this article.
Comments
There are no comments for this article. Be the first to post a comment.
Name
Email
Security Code Security Code
Related Articles RSS Feed
Power - Wind Power Testing at UNAVCO through 2005, Phase 3
Viewed 3544 times since Sat, Mar 27, 2010
Power - Wind Power Testing at UNAVCO through 2005, Phase 2
Viewed 3395 times since Sat, Mar 27, 2010
Power - Wind Power Testing at UNAVCO through 2005, Phase 1
Viewed 3433 times since Sat, Mar 27, 2010
Power - Wind Power Testing at UNAVCO through 2005 (summary)
Viewed 2591 times since Sat, Mar 27, 2010
Trimble NetR9 Power Consumption
Viewed 7080 times since Tue, Oct 4, 2011
Wind Power for Remote DC Powered Stations (2003)
Viewed 2518 times since Sat, Mar 27, 2010
Equipment Power Usage Testing
Viewed 8764 times since Sun, Mar 28, 2010
Javad Sigma Power Consumption
Viewed 6109 times since Wed, Oct 5, 2011
SLA Battery Cold Performance Tests: Gel vs. AGM
Viewed 14473 times since Sun, Mar 28, 2010
Power Draw Profile for Trimble NetRS and Iridium Systems
Viewed 5699 times since Sat, Aug 28, 2010
MENU

Last modified: Monday, 12-May-2014 00:18:29 UTC