| UNAVCO
 


Knowledge Base

Trimble NetR9 Power Consumption

The mean power consumption during a 12 hour test of the Trimble NetR9 receiver was: 3.67 W



Testing Procedure:
  • Input: 16 V
  • Agilent N6705B DC power analyzer
  • Power sampling rate: 10 Hz
  • Test was conducted at room temperature
  • Tracking GPS L1/L2 only
  • Logging one 15 second session
  • Ethernet port was connected (increases power use by ~0.1W)
  • Connected to a TRM59800.00 antenna
  • USB thumb drive attached (increases power use by ~0.4W)
  • Firmware version 4.43
Attached Files
There are no attachments for this article.
Comments
There are no comments for this article. Be the first to post a comment.
Name
Email
Security Code Security Code
Related Articles RSS Feed
Power - Wind Power Testing at UNAVCO through 2005, Phase 3
Viewed 4788 times since Sat, Mar 27, 2010
Power - Wind Power Testing at UNAVCO through 2005, Phase 2
Viewed 5269 times since Sat, Mar 27, 2010
Trimble NetR9 power draw tests
Viewed 313 times since Thu, Jul 29, 2021
Summary Report on Forgen 500 Wind Turbine Performance (2007)
Viewed 8828 times since Sat, Mar 27, 2010
Septentrio PolaRx5 Power Consumption
Viewed 4559 times since Fri, Jan 8, 2016
Javad Sigma Power Consumption
Viewed 7449 times since Wed, Oct 5, 2011
Trimble NetRS - Power Draw Tests
Viewed 5899 times since Sun, Mar 28, 2010
Power - Wind Power Testing at UNAVCO through 2005, Phase 1
Viewed 4498 times since Sat, Mar 27, 2010
Power Draw Profile for Trimble NetRS and Iridium Systems
Viewed 6824 times since Sat, Aug 28, 2010
Topcon Net-G3A Power Consumption
Viewed 4151 times since Mon, Oct 10, 2011
MENU
 

Last modified: 2019-12-27  16:36:35  America/Denver