Trimble NetR5, NetR8 and NetR9 - Critical Power-On/Off Configuration Details

NetR5, NetR8, and NetR9 hardware requires that Power On and Shutdown Voltages be properly configured to ensure proper functionality when used with DC power systems. 

UNAVCO has determined, and Trimble has confirmed, that a NetR5, NetR8, or NetR9  configured with a Power On Voltage that is not more than 1 Volt greater than the Shutdown Voltage will not power on as programmed under certain circumstances.  UNAVCO suggests that a minimum separation of 1.3 Volts be used.

These settings are found in the "General" submenu of the "Receiver Configuration" menu of the web interface.  UNAVCO recommends the following configurations, depending on the type of Charge Controller being used:

1.  If a Charge Controller without a Low Voltage Disconnect (LVD) is used:
Power On Voltage: 12.50V
Shutdown Voltage: 11.00V





2.  If a Charge Controller WITH an LVD is used:  identify the voltage thresholds of the LVD and set the receivers voltages below each of them.  A commonly used controller - the Flexcharge NC30 - will disconnect the load when battery voltage drops below 10.9V and reconnect at 12.9V.  The NetR9 should then be set to:
Power On Voltage: 12.80V
Shutdown Voltage: 10.80V




Users should consider the effects of these settings on their power systems and may adjust them according to need, but should be careful to adhere to the minimum separations.  Please contact UNAVCO for advice and assistance testing individual configurations, and for further details.

While future versions of firmware may add enhancements to the user interface that will explicitly warn users of the configuration requirements and change the defaults accordingly, this is a hardware-based feature and will always be present in these receivers.

Attached Files
There are no attachments for this article.
Comments
There are no comments for this article. Be the first to post a comment.
Name
Email
Security Code Security Code
Related Articles RSS Feed
Trimble NetR5, NetR8, and NetR9 Receivers: Hint for Using Web Interface With Slow Connection
Viewed 3283 times since Fri, Apr 29, 2011
Trimble NetR9 - How to enable an external frequency source
Viewed 6929 times since Thu, Feb 27, 2014
Trimble NetR5 Resource Page
Viewed 6765 times since Tue, Jun 1, 2010
Imaging a Trimble NetRS receiver compact flashcard
Viewed 1381 times since Tue, Mar 31, 2015
How to access Trimble NetR9 through USB
Viewed 4046 times since Tue, Aug 2, 2011
Accessing the NetRS/NetR8/NetR9 programmatic interface with linux curl command
Viewed 19804 times since Thu, Apr 5, 2012
Trimble NetR5 - User Guide v3.10, Rev. A, March 2006
Viewed 1451 times since Tue, Aug 25, 2009
Trimble NetR8 Resource Page
Viewed 7322 times since Tue, Feb 19, 2013
Trimble NetR9 Resource Page
Viewed 34373 times since Mon, Aug 17, 2015
Using external USB memory and logging sessions - Trimble NetR9
Viewed 50379 times since Tue, May 6, 2014
MENU

Last modified: Monday, 12-May-2014 00:18:29 UTC