Intuicom - How to run diagnostics on Intuicom ethernet bridges using CommPro

How to run diagnostics on Intuicom ethernet bridges using CommPro

Local diagnostics: Diagnostics on sending and receiving only at the radio to which the computer is attached.

Remote diagnostics: Diagnostics of all/any connections from the master radio.

To run local diagnostics:

  1. Enable local diagnostics on the radio (1).

  2. Enable local access if it is not enabled already.

  3. Check for good signal-to-noise ratio (SNR); green is good.

  4. Check VSWR (reflective power). A value in the low single digits is best but sometimes the link will work up to a value of 20. If it works, the statistic is not important. We have remade antenna cables in attemps to lower this value without success. (This feature in Local Diagnostics appears to be broken at the time of writing; value reads 0.)

To run remote diagnostics:

  1. Enable diagnostics on the master; this will override slave settings (i.e. this will still work if the slaves are disabled). Common settings are in the range of 15-30.

  2. Check decode success. Try for >90; >80 is still okay. We have working radio shots in the 70s, but generally the signal is too weak <70. Note that the decode success will fluctuate with moisture. Some shots in California fluctuate by as much as 20 percent, from 60-80. Some days the shots work and some days they don’t.

  3. If the master radio is connected to e.g. a Lantronix CDMA modem, you can run diagnostics remotely. Leave the network configured for diagnostics. You can then configure the network remotely as well, by making changes from the slaves up.

The "Help" function within CommPro is informative and can be consulted for more detailed information on settings.

Note that some settings look different in different modules within CommPro, e.g. a frequency key of A in one module is expressed as a 10 in another, and a diagnostics setting of 30 in one module is expressed as 291 in another.

 

eb,bab2009

Attached Files
There are no attachments for this article.
Comments
There are no comments for this article. Be the first to post a comment.
Name
Email
Security Code Security Code
Related Articles RSS Feed
Intuicom CommPro Datasheet
Viewed 1057 times since Mon, Oct 5, 2009
CommPro 1.1.2
Viewed 776 times since Tue, Mar 24, 2009
Intuicom CommPro System Requirements
Viewed 1084 times since Tue, Oct 6, 2009
CommPro 1.0.25
Viewed 807 times since Tue, Mar 24, 2009
CommPro 1.1.7
Viewed 951 times since Wed, Apr 22, 2009
CommPro 1.1.3
Viewed 776 times since Tue, Mar 24, 2009
CommPro 1.1.4
Viewed 1116 times since Tue, Mar 24, 2009
CommPro 1.1.11 (most recent)
Viewed 1220 times since Wed, Apr 22, 2009
Intuicom - How to configure an Intuicom wireless Ethernet bridge using CommPro software
Viewed 2416 times since Wed, Jan 27, 2010
MENU

Last modified: Monday, 12-May-2014 00:18:29 UTC