How to enable 20 Hz (and other high-rate) logging in Topcon GB-1000 Receivers

Topcon GB-1000 - How to enable 20 Hz (and other high-rate) logging

GB-1000 receivers are capable of logging at 20 Hz (50 ms.) sample rate, but in addition to specifying the sample rate for the log file two other receiver parameters must also be specified.

The internal "Raw Measurement Update" (pos/msint) and "Position Update"(raw/msint) parameters are set to 10 Hz (100 ms.) by default.  This limits the logging rate to 10 Hz minimum or other sampling rates that are multiples of 100 ms. (10 Hz, 5 Hz, 3.33 Hz, 2.5 Hz, 2 Hz, 1 Sec., etc.).   In order to attain 20 Hz (or other sampling intervals that are multiples of 50 ms. such as 4 Hz).

If using a GRIL configuration script the following lines should be used to enable 20 Hz:

%/par/pos/msint%set,/par/pos/msint,50  #Position Update Interval 50 ms (20 Hz)
%/par/raw/msint%set,/par/raw/msint,50  #Raw Update Interval 50 ms (20 Hz)

followed by the command to specify the sample rate in the log file:

%ope% set,/par/log/a/sc/period,0.05    #Logging Interval 0.05 sec (20 Hz)

If using PC-CDU, the "Raw Measurement Update" and "Position Update" parameters are set in the "Advanced/Raw Data Management" tabs of the receiver configuration menu, as shown in the screen shot below:

It is currently now possible to enable logging rates faster than 1 Hz from the front panel of the receiver. We have requested this capability of Topcon in a future firmware release.

Attached Files
There are no attachments for this article.
Comments
There are no comments for this article. Be the first to post a comment.
Name
Email
Security Code Security Code
Related Articles RSS Feed
Topcon GB-1000 - How to configure for static surveying
Viewed 3196 times since Fri, Jan 9, 2009
Topcon GB1000 - Como bajar datos
Viewed 1064 times since Mon, Mar 22, 2010
Topcon GB-1000 - How to configure for rapid static observations
Viewed 2516 times since Fri, Jan 9, 2009
Topcon GB-1000 - How to configure for kinematic surveys
Viewed 2533 times since Fri, Jan 9, 2009
How to download a Topcon GB-1000 receiver using lftp
Viewed 4137 times since Wed, Sep 9, 2009
Topcon GB-1000 - How to download data
Viewed 3404 times since Fri, Jan 9, 2009
MENU

Last modified: Monday, 12-May-2014 00:18:29 UTC