Septentrio PolaRx5 Power Consumption

  • All values were measured using an Agilent DC Power Analyzer
    • Power consumption was measured at 12 V
  • Measured values are given with 10% margin of error
    • Power values will fluctuate with the number of visible satellites tracked
  • Users must turn off both satellite and signal tracking to realize power consumption reductions
Criteria GPS L1 and L2 only (W) GPS L1, L2, & L5 (W) GPS and GLONASS (W) All Constellations in view (W)
Minimum possible power consumption 2.0 2.3 2.3 3.1
Ethernet Off - Logging 15-sec Session 2.2 2.4 2.4 3.2

Ethernet Off - Logging 15-sec Session &

1 Hz Session

2.2 2.4 2.4 3.2

Ethernet Off - Logging 15-sec Session & 

10 Hz Session

2.2 2.4 2.4 3.2

Ethernet On - Logging 15-sec session &

1 Hz Session

2.9 3.1 3.1 4.0

Ethernet On - Logging 15-sec session &

1 Hz TCP/IP stream

2.9 3.1 3.1 4.0

Ethernet On - Logging 15-sec Session &

1 Hz Session & 10 Hz TCP/IP stream

2.9 3.1 3.1 4.0
Maximum possible power consumption       4.3
Posted by: Henry Berglund - January 8, 2016. This article has been viewed 747 times.